HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

Table 7-30 HP_MemoryHardwareIndication: Memory Recovered from Degraded Redundancy
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddress Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
VariableNames Tag or InstanceID
Indicates that the
HP_MemoryRedundancySet.InstanceID value is
populated in property VariableValues.
VariableTypes 1 (string)
VariableValues String containing the
HP_MemoryRedundancySet.InstanceID value.
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists