HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddress Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames Tag or InstanceID
Indicates that the
HP_MemoryRedundancySet.InstanceID value is
populated in property VariableValues.
VariableTypes 1 (string)
VariableValues String containing the
HP_MemoryRedundancySet.InstanceID value.
ImpactedDomain 3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HP_MemoryHardwareIndication