HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
IndicationIdentifier GUID string generated at the time of indication
IndicationTime Time of indication
CIM_ProcessIndication
CIM_AlertIndication
Description The Advanced Memory Protection (AMP) system is
operating with degraded redundancy. The targeted
configuration has degraded or is operating with
memory modules that have failed or predicted to fail.
(TargetConfiguration/CurrentConfiguration), where
TargetConfiguration is
HP_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 5 (Major)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Advanced Memory Protection Degraded
RecommendedActions Check the Advanced Memory Protection configuration
and replace the memory board and memory modules
as necessary. Repair appropriate IML log messages
after memory is replaced.
EventID 3
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.SystemName
ProviderName HP Memory
HP_AlertIndication
Summary Advanced Memory Protection degraded
EventCategory 3 (Memory)
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>