HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

Table 7-28 HP_MemoryHardwareIndication: Memory Board Error
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
VariableNames Tag or InstanceID
Indicates that the HP_MemoryBoard.Tag value for the
failing memory board is populated in property
VariableValues.
VariableTypes 1 (string)
VariableValues String containing the HP_MemoryBoard.Tag value for
the failing memory board
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HP_MemoryHardwareIndication
AlertType 5 (Device Alert)
7-5-3 Memory Redundancy Degraded