HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
Table 7-28 HP_MemoryHardwareIndication: Memory Board Error
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 5 (Major)
ProbableCause 1 (Other)
ProbableCauseDescription Memory Board Error
RecommendedActions Check the memory configuration and replace the
memory board and memory modules as necessary.
Repair appropriate IML log messages after memory is
replaced.
EventID 2
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.SystemName
ProviderName HP Memory
HP_AlertIndication
Summary Memory board error
EventCategory 3 (Memory)
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
Network Address Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication