HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
Table 7-9 Class: HP_MemoryCollection
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
GroupOperationalStatus Enumerator indicating the group operational status of
the memory collection. The status is determined as
follows:
If an instance of HP_MemoryRedundancySet exists,
GroupOperationalStatus[0] is determined from the
property
HP_MemoryRedundancySet.RedundancyStatus.
If no instance of HP_MemoryRedundancySet exists,
GroupOperationalStatus[0] is determined by the
‘worst-of’ algorithm for physical memory boards
and memory modules.
For details, see the Memory Collection Status.
GroupStatusDescriptions GroupStatusDescriptions[0] contains descriptive text
per GroupOperationalStatus[0]:
Memory collection status: OK
Memory collection status: Degraded
Memory collection status: Unknown
HP_MemoryCollection
Table 7-10 Memory Collection Status
RedundancyStatus
from
HP_MemoryRedundanc
y
Set
‘worst’
OperationalStatus[0],
HP_MemoryBoard
‘worst’
OperationalStatus[0],
HP_MemoryModule
GroupOperationalStatus
[0]
2 (Fully Redundant) — — 2 (OK)
3 (Degraded Redundancy) — — 3 (Degraded)
— 2 (OK) 2 (OK) 2 (OK)
— 2 (OK) 3 (Degraded) 3 (Degraded)
—
2 (OK) 0 (Unknown) 0 (Unknown)
— 3 (Degraded) 2 (OK) 3 (Degraded)
— 3 (Degraded) 3 (Degraded) 3 (Degraded)
— 3 (Degraded) 0 (Unknown) 3 (Degraded)
— 0 (Unknown) 2 (OK) 0 (Unknown)
— 0 (Unknown) 3 (Degraded) 3 (Degraded)
— 0 (Unknown) 0 (Unknown) 0 (Unknown)
7-4-7 HP_HostedMemoryCollection
The class HP_HostedMemoryCollection represents an association between HP_MemoryCollection and
the computer system that contains this collection.