HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

Table 6-8 HP_SensorHardwareIndication: Temperature Sensor Caution Threshold Exceeded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
Description A temperature sensor has detected that the temperature
has exceeded the normal operating range.
(SensorCaption) where
SensorCaption is the HP_WinNumericSensor.Caption
for the sensor that has failed.
AlertingManagedElement WBEM path of the HP_WinNumericSensor instance
representing the temperature sensor detecting the
exceeded threshold
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP Temperature
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Temperature Cautionthreshold exceeded detected.
EventCategory 23 (System Cooling)
ProbableCause 51 (Temperature Unacceptable)
ProbableCauseDescription Temperature Caution Threshold Exceeded Detected
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication