HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
Table 5-23 Hp_SensorHardwareIndication: Fan Repaired
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has been repaired. The fan is now operating
properly. (FanCaption), where FanCaption is the
HP_WinFan.Caption for the fan that has been repaired
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the failed fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
ProviderName HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan Repaired.
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Repaired
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication