HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
5-4-4 Fan Degraded
Table 5-22 Hp_SensorHardwareIndication: Fan Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has been degraded. (FanCaption), where
FanCaption is the HP_WinFan.Caption for the fan that
has been degraded.
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the degraded Fan.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 9
ProviderName HP Cooling
RecommendedActions Check the degraded fan and replace if necessary..
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan Degraded.
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Degraded due to Single Rotor Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>