HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
Table 5-20 HP_SensorHardwareIndication: Fan Inserted
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-3 Fan Failed
Table 5-21 HP_SensorHardwareIndication: Fan Failed
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has failed. (FanCaption), where FanCaption is the
HP_WinFan.Caption for the fan that has failed
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the failed fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP Cooling
RecommendedActions Check the failed fan and replace if necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan failed
EventCategory 23 (System Cooling)
ProbableCause 94 (Fan Failure)
ProbableCauseDescription Fan Failed
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication