Table 5-19 HP_SensorHardwareIndication: Fan Removed
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-2 Fan Inserted
Table 5-20 HP_SensorHardwareIndication: Fan Inserted
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has been inserted. (FanCaption), where
FanCaption is the HP_WinFan.Caption for the fan that
has been inserted
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the inserted fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan Inserted
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Inserted
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>