HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

5-3-3 HP_CoolingRedundancySet
HP_CoolingRedundancySet is used to model fan redundancy sets on ProLiant servers. The Windows®
implementation class is HP_WinCoolingRedundancySet.
Table 5-4 Class: HP_CoolingRedundancySet
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_ManagedElement
Caption Cooling Redundancy Set n
n represents the number of the redundancy set instance
Description Cooling Redundancy Set n is collection of fault tolerant
fans that provide redundant cooling.
n represents the number of the redundancy set instance
ElementName Cooling Redundancy Set n, where n represents the
number of the redundancy set instance
CIM_SystemSpecificCollection
InstanceID Unique identifier for this cooling redundancy instance
CIM_RedundancySet
MaxNumberSupported Represents the maximum number of fans supported for
this redundancy set
MinNumberNeeded Represents the minimum number of fans needed to
function
TypeOfSet 3 (Load Balanced)
LoadBalanceAlgorithm 0 (Unknown)
RedundancyStatus
0 (Unknown)—If the redundancy status is unknown
2 (Fully Redundant)—If the all fans in the set are
operating properly and enough to achieve
redundancy
3 (Degraded Redundancy)—If there are at least
enough fans for the redundancy set to provide
cooling, but fans have failed
4 (Redundancy Lost)—If there are not enough fans
required to achieve redundancy, but enough for the
redundancy set to provide cooling
5 (Overall Failure)—If there are not enough fans
operating properly for the redundancy set to
provide cooling.
5-3-4 HP_MemberOfCoolingRedundancy
HP_MemberOfCoolingRedundancy is used to represent an association between HP_Fan and
HP_CoolingRedundancySet. The Windows® implementation class is
HP_WinMemberOfCoolingRedundancy.