HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 4-31 HP_SensorHardwareIndication: Power Supply Redundancy Restored
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-9 Power Supply Failed due to Input Power Loss
Table 4-32 HP_SensorHardwareIndication: Power Supply Failed due to Input Power Loss
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A power supply has failed—Input power lost
(PowerSupplyCaption), where PowerSupplyCaption is the
HP_WinPowerSupply.Caption for the power supply
that has failed.
AlertingManagedElement WBEM path of the HP_WinPowerSupply instance
representing the failed power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 9
ProviderName HP Power
RecommendedActions Check the input power being supplied to the failed
power supply and reconnect power.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power supply failed - input power lost
EventCategory 16 (System Power)