HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 4-28 HP_SensorHardwareIndication: Power Supply Redundancy Reduced
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-6 Power Supply Redundancy Lost
Table 4-29 HP_SensorHardwareIndication: Power Supply Redundancy Lost
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description Power redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinPowerRedundancySet.Caption
for the redundancy set that lost redundancy.
AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet
instance representing the redundancy set where
redundancy was lost.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 6
ProviderName HP Power
RecommendedActions Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power
supplies if necessary
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power redundancy lost
EventCategory 16 (System Power)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Power Redundancy has been Lost