HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 4-27 HP_SensorHardwareIndication: Power Supply Repaired
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-5 Power Supply Redundancy Reduced
Table 4-28 HP_SensorHardwareIndication: Power Supply Redundancy Reduced
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fault tolerant power supply is no longer providing
power for a power redundancy set.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinPowerRedundancySet.Caption
for the redundancy set with reduced redundancy.
AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet
instance representing the redundancy set with reduced
redundancy.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 5
ProviderName HP Power
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power redundancy reduced
EventCategory 16 (System Power)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Power Redundancy has been Reduced
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>