HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 4-25 HP_SensorHardwareIndication: Power Supply Inserted
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-3 Power Supply Failed
Table 4-26 HP_SensorHardwareIndication: Power Supply Failed
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A power supply has failed. (PowerSupplyCaption),
where PowerSupplyCaption is the
HP_WinPowerSupply.Caption for the power supply
that has failed.
AlertingManagedElement WBEM path of the HP_WinPowerSupply instance
representing the failed power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP Power
RecommendedActions Check the failed power supply, and replace if
necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power supply failed.
EventCategory 16 (System Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Power Supply Failed
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication