HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 23-35 HP_SATADeviceIndication: Disk Drive status Predictive Failure
Property name
Property implementation
PerceivedSeverity
3 (Degraded/Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Disk Drive status has changed to Predictive Failure.
AlertingManagedElement
WBEM path of the HP_SATADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
605
ProviderName
HP SATA
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive status Predictive Failure.
EventCategory
6 (Primary Storage Device)
ProbableCause
1 (Other)
ProbableCauseDescription
Disk Drive State Changed to Predictive Failure
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication