HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 18-38 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down
Property name
Property implementation
EventID
6
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Fibre Channel
RecommendedActions
1 Check the FC cabling to this port
2 Reinsert the FC GBIC if it has been unplugged
3 Replace FC cabling or the FC GBIC if failure continues
SystemName
HP_ComputerSystem.SystemName
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
FC HBA port in link down state
EventCategory
11 (I/O Adapter)
ProbableCause
5 (Connection Establishment Error)
ProbableCauseDescription
FC HBA Port State Changed to Link Down
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication