HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 17-76 HPSCSI_DeviceIndication: Temperature sensor status change OK
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Enclosure firmware version string
HWLogicalLocation
Enclosure Location string
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
17-4-16 Temperature sensor status change Warning Condition
Table 17-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingMangedElement
WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
308
ProviderName
HP SCSI
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.