HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 17-74 HPSCSI_DeviceIndication: Power Supply status OK
Property name
Property implementation
DeviceModel
Enclosure Model string
17-4-14 Power Supply Status DEGRADED
Table 17-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Supply status has changed
to Degraded Redundancy
AlertingMangedElement
WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
303
ProviderName
HP SCSI
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Power supply status Redundant Degraded.
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription
Redundant Power Supply Degraded
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication