HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 17-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Supply status has
changed to non-redundant
AlertingMangedElement
WBEM path of the
HPSCSI_StorageEnclosureProcessor class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
301
ProviderName
HP SCSI
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary
SystemName
Name of the computer system generating the
indication
SystemCreationClassName
CreationClassName of the computer system
generating the indication
HP_AlertIndication
Summary
Power Supply status Non-Redundant
EventCategory
17 (Primary Storage Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113