HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 17-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A SCSI physical drive with a status of Error that was
located in the system has been removed
AlertingMangedElement
WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
7
ProviderName
HP SCSI
RecommendedActions
Check for failed or removed physical drives
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive missing was Error
EventCategory
6 (Primary Storage)
ProbableCause
73 (Element Missing)
ProbableCauseDescription
Missing Physical Drive was Error.
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication