HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 17-65 HPSCSI_DeviceIndication: Physical Drive status OFFLINE
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
6 (Critical)
IndicationTime
Time of indication
CIM_AlertIndication
Description
The physical drive is offline and can no longer return
data. No further status is available.
AlertingMangedElement
WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
10
ProviderName
HP SCSI
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive offline.
EventCategory
6 (Primary Storage)
ProbableCause
72 (Element unavailable)
ProbableCauseDescription
Physical Drive Offline
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication