HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

Table 2-25 HP_SystemHardwareIndication: DL980 System configuration (current hyper-threading mode
disabled) is not optimal
Property name
Property implementation
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
2-4-10 Threshold Indication - Average CPU Utilization Warning
Threshold Exceeded
Table 2-15 HP_ThresholdIndication: Average CPU Utilization Warning threshold exceeded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded/Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
The Average CPU utilization Warning threshold has
exceeded for CPU :(CPU Name)
AlertingElementFormat
1 (Unknown)
AlertType
1 0x1 (Other)
EventID
2
ProviderName
HP CPU Threshold
RecommendedActions
None
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
ProbableCause
1 0x1 (Other)
ProbableCauseDescription
CPU Warning threshold exceeded
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemGUID
Platform GUID of the computer system generating the
indication
ImpactedDomain
 3 (Enclosure) for c-Class BladeSystems
 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the
properties indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists