HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 16-96 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
Description
A Storage Enclosure Fan Status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingMangedElement
WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
306
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status Error
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan failure)
ProbableCauseDescription
Fan Failure
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication