Table 16-93 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs.
AlertingMangedElement
WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
309
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor status Critical
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51 (Temperature Unacceptable )
ProbableCauseDescription
Temperature Status Changed to Critical
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113