HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 16-92 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
308
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor status Warning Condition
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Temperature Status Changed to Warning Condition
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication