2-4-14 Enclosure Power Supply Status changed to Redundant
Degraded
Table 16-90 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement
WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
303
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Power supply status Redundant Degraded
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power supply failure)
ProbableCauseDescription
Redundant Power Supply Degraded
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication