HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 16-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
Property implementation
HP_DeviceIndication
DeviceModel
Disk Model string
2-4-7 Physical Drive status Predictive Failure – Solid State
Wear out
Table 16-83 HPSAS_DeviceIndication: Drive status Predictive Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Due to Solid State wear out a physical drive status has
changed to Predictive Failure.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
311
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive status Predictive Failure..
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
A Solid State wear out has Changed Physical Drive
Status to Predictive Failure.