HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 16-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
Property implementation
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
VariableNames
FailureDescription
VariableTypes
1 (String)
VariableValues
Short Description of failure
In some cases, the property VariableValues can have
N/A or ―‖ values.
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Disk firmware version string
HWLogicalLocation
Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number