HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 15-134 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor Status changed to Warning
Condition.
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
VariableNames
FailureDescription
VariableTypes
1 (String)
VariableValues
Short description of failure
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name