HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
15-4-30 Enclosure Power Supply Status Changed
to Redundant Degraded
Table 15-132 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement
WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
303
ProviderName
HP Smart Array
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Power Supply Status Redundant Degraded.
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power supply failure)
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>