HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 15-127 HPSA_DeviceIndication: Controller Cache statusDegraded
Property name
Property implementation
HWLogicalLocation
Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-26 Controller Cache Status - Failed
Table 15-128 HPSA_DeviceIndication: Controller Cache statusFailed
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Error)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array Controller Cache Status has changed to
Failed.The
controller has detected a problem with the cache and
has failedthe cache.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
11
ProviderName
HP Smart Array
RecommendedActions
Check the cache controller error code and run
diagnostics.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Array controller cache status failed.
EventCategory
6 (Primary Storage)
ProbableCause
35 (Performance Degraded)