HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 15-118 HPSA_DeviceIndication: Controller status changed to OK
Property name
Property implementation
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-17 Controller Status Changed to ERROR
Table 15-119 HPSA_DeviceIndication: Controller status changed to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Array Controller Status has changed to a status of
ERROR
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Smart Array
RecommendedActions
Check controller status. Run Diagnostics.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Controller Status changed to Error
EventCategory
6 (Primary Storage)
ProbableCause
24 (I/O device error)
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113