HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded - multipath failure
Property name
Property implementation
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive is in a degraded state. Multipath
support is Lost. Either cable is removed or not
configured.
AlertingMangedElement
WBEM path of the HPSA_StorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
104
ProviderName
HP Smart Array
RecommendedActions
Check status of Logical drives. Degraded status may be
caused by multipath failure.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical drive in degraded state - multipath failure.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication