HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
15-4-10 Logical Drive Status Changed to ERROR
Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Logical Drive Status has changed to Error .
AlertingMangedElement
WBEM path of the HPSA_StorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
102
ProviderName
HP Smart Array
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical Drive Status error
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion
Firmware version of the computer system generating
the indication