HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 15-43 HPSA_DeviceIndication: Physical Drive status changed to Secure Erase State
Property name
Property implementation
HWFirmwareVersion
Physical Disk firmware version string
HWLogicalLocation
Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation
Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer
HP
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
15-4-6 Physical Drive Status Changed to OK
Table 15-44 HPSA_DeviceIndication: Physical Drive status changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Informational))
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive is in Online state. After Secure Erase
Operation
AlertingMangedElement
WBEM path of the HPSA_DiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
206
ProviderName
HP Smart Array
RecommendedActions
No action is recommended
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical Drive status Online