HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 15-42 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Property implementation
VariableTypes
VariableTypes[0]: 1 (String)
VariableTypes[1]: 1 (String)
VariableTypes[2]: 4 (uint16))
VariableValues
VariableValues[0]: Short Description of failure
VariableValues[1]: Short Description of last failure
VariableValues[2]: HPSA_DiskDrive.DriveInterface
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Physical Disk firmware version string
HWLogicalLocation
Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation
Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer
HP
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string