Table 15-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name
Property implementation
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation
Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer
HP
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
15-4-3 Physical Drive Status Changed to REBUILDING
Table 15-41 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Rebuilding.
Data is now being rebuilt onto this drive from the RAID
set
AlertingMangedElement
WBEM path of the HPSA_DiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
203
ProviderName
HP Smart Array
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical Drive is now Rebuilding
EventCategory
6 (Primary Storage)
ProbableCause
1 (Other)