HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

2-3-7 HP_PowerManagementElementCapabilities
HP_PowerManagementElementCapabilities extends the class CIM_ElementCapabilities and associates
the HP_PowerManagementService instance and the HP_PowerManagementCapabilities instance.
Only one instance of HP_PowerManagementElementCapabilities is instantiated on a ProLiant server.
The following properties are implemented.
Table 2-9 Class: HP_PowerManagementElementCapabilities
Property name
Property implementation
CIM_ElementCapabilities
HP_PowerManagementElementCapabilities
ManagedElement
ref: HP_PowerManagementService
Capabilities
ref: HP_PowerManagementCapabilities
2-3-8 HP_HostedPowerManagementService
HP_HostedPowerManagementService extends the class CIM_HostedService and associates the
HP_ComputerSystem instance and the HP_PowerManagementService instance. Only one instance of
HP_HostedPowerManagementService is instantiated on a ProLiant server.
The following properties are implemented.
Table 2-10 Class: HP_HostedPowerManagementService
Property name
Property implementation
CIM_Dependency
CIM_HostedDependency
CIM_HostedService
HP_HostedPowerManagementService
Antecedent
ref: HP_ComputerSystem
Dependent
ref: HP_PowerManagementService
2-3-9 HP_SystemROMFirmware
HP_SystemROMFirmware extends the class CIM_SoftwareIdentity to model the server system ROM
BIOS.
The following properties are implemented.
Table 2-11 Class: HP_SystemROMFirmware
Property name