HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 13-25 HP_AlertIndication: Ethernet Team Redundancy Lost
Property name
Property implementation
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
13-4-2 Ethernet Team Redundancy Increased
Table 13-26 HP_AlertIndication: Ethernet Team Redundancy Increased
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
An Ethernet team's redundancy has increased. A team
member recovered from a failed or degraded state.
AlertingManagedElement
WBEM path of the Ethernet Team
(HP_WinEthRedundancySet) reporting increased
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
2 (Communications Alert)
Event Id
6
ProviderName
HP Ethernet
RecommendedActions[]
No action is recommended.
SystemCreationClassName
CreationClassName of the computer system generating
the indication
SystemName
Name of the computer system generating the indication
HP_AlertIndication
Summary
Ethernet team redundancy increased.
EventCategory
9 (Network Device)
EventSubCategory
12 (Ethernet Team)
13 (Ethernet LAN Endpoint)