HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

Management Processor Lite 207
Table 9-2 Class: HP_ManagementProcessor
Property name
Property implementation
StatusDescriptions
Descriptive text per OperationalStatus.
StatusDescriptions[0] text per OperationalStatus[0]:
○ Management Processor Status: Unknown
○ Management Processor Status: OK
○ Management Processor Status: Degraded
○ Management Processor Status: Error
StatusDescriptions[1] text per OperationalStatus[1]:
○ Management Processor NIC Status: Unknown
○ Management Processor NIC Status: OK
○ Management Processor NIC Status: NIC is
disabled
○ Management Processor NIC Status: Not in use,
MP is utilizing host NIC
○ Management Processor NIC Status: NIC
disconnected
○ Management Processor NIC Status: NIC failed
HealthState
0 (Unknown), when OperationalStatus[0]=0
(Unknown), or when software interface fails
5 (OK), normal operation
10 (Degraded/Warning), when
OperationalStatus[0]=3 (Degraded)
20 (Major failure), when OperationalStatus[0]=6
(Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState
2 (Enabled) for active MP
3 (Disabled) for inactive/disabled MP
RequestedState
12 (Not Applicable)
EnabledDefault
2 (Enabled)
CIM_System
CreationClassName
HP_ManagementProcessor
Name
Product name of the management processor
Examples:
Remote Insight Board Lights Out Edition II (RILOE-II)
Integrated Lights Out (iLO)
Integrated Lights Out 2 (ILO2)
CIM_ComputerSystem
Dedicated
14 (Management)
ResetCapability
4 (Enabled)
HP_ManagementProcessor