HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

Management Processor Lite 206
Table 9-2 Class: HP_ManagementProcessor
Property name
Property implementation
Description
Description of the Management Processor in the
format: <X> HP Management Processor - <product
name> where <X> indicates the MP Is Active or
Inactive/Disabled and <product name> is the name of
the MP product (same as the product name in property
ElementName)
For example, Active HP Management Processor –
Integrated Lights Out (iLO)
ElementName
Product name of the management processor.
Examples:
Remote Insight Board Lights Out Edition II (RILOE-II)
Integrated Lights Out (iLO)
Integrated Lights Out 2 (ILO2)
CIM_ManagedSystemElement
OperationalStatus
Enumerators indicating the Management Processor
operational status (refer to OperationalStatus mapping
table in HP Management Processor (MP) Lite Profile for
specific descriptions of when each value is populated).
OperationalStatus[0] contains MP operational
status:
○ 0 (Unknown), when NICCondition=0
○ 2 (OK), normal operation
○ 3 (Degraded), when NICCondition=5
○ 6 (Error), when NICCondition=6 or MP
software interface fails
OperationalStatus[1] contains NIC status (when MP
is enabled):
○ 0 (Unknown), when NICCondition=0 or MP
software interface fails
○ 2 (OK), normal operation
○ 3 (Degraded), when NICCondition=5
○ 6 (Error), when NICCondition=6
○ 10 (Stopped), when NICCondition=3
○ 15 (Dormant), when NICCondition=4