HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 7-28 HP_MemoryHardwareIndication: Memory Board Error
Property name
Property implementation
Network Address
Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
VariableNames
Tag or InstanceID
Indicates that the HP_MemoryBoard.Tag value for the
failing memory board is populated in property
VariableValues.
VariableTypes
1 (string)
VariableValues
String containing the HP_MemoryBoard.Tag value for
the failing memory board
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HP_MemoryHardwareIndication