HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 7-28 HP_MemoryHardwareIndication: Memory Board Error
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
IndicationTime
Time of indication
CIM_ProcessIndication
CIM_AlertIndication
Description
A memory board has an error. (MemoryBoardCaption)
where MemoryBoardCaption is the
HP_MemoryBoard.Caption for the failing memory
board.
AlertingManagedElement
WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat
2 (CIMObjectPath)
PerceivedSeverity
5 (Major)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Board Error
RecommendedActions
Check the memory configuration and replace the
memory board and memory modules as necessary.
Repair appropriate IML log messages after memory is
replaced.
EventID
2
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.SystemName
ProviderName
HP Memory
HP_AlertIndication
Summary
Memory board error
EventCategory
3 (Memory)
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>