HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 7-27 HP_MemoryHardwareIndication: Memory Module Predictive Failure
Property name
Property implementation
Description
A memory module has failed or is predicted to fail.
(MemoryModuleCaption), where MemoryModuleCaption
is the HP_MemoryModuleCaption for the failing
memory module.
AlertingManagedElement
WBEM Path of HP_MemoryModule instance
representing the memory module
AlertingElementFormat
2 (CIMObjectPath)
PerceivedSeverity
5 (Major)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Module Failed or Predicted to Fail
RecommendedActions
Check the memory configuration and replace memory
as necessary. Repair appropriate IML log messages
after memory is replaced.
EventID
1
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.SystemName
ProviderName
HP Memory
HP_AlertIndication
Summary
Memory module has failed or is predicted to fail
EventCategory
3 (Memory)
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddress
Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication