HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 7-8 Class: HP_MemoryRedundancySet
Property name
Property implementation
ConfigurationsAvailable
An array containing Advanced Memory Protection
configurations supported on this system (the
CurrentConfiguration and TargetConfiguration
properties will contain one of these values). Each
indexed position in the array contains one supported
configuration.
Possible values are:
Advanced ECC
Online Spare
Online Spare Rank
Online Spare Channel
Mirroring
Single Board Mirroring
Dual Board Mirroring
Mirrored Intrasocket
Mirrored Intersocket
RAID-XOR
Lockstep
OperatingVoltage
This value specifies the current operating voltage
of the Advanced Memory Protection subsystem in
millivolts. If this system does not support
Advanced Memory Protection or value cannot be
determined, then a value of 0 will be returned.
7-4-6 HP_MemoryCollection
The class HP_MemoryCollection represents physical memory collections on ProLiant servers. The
collection comprehends physical memory modules and boards as components of the collection. There
is one instance of this class.
Table 7-9 Class: HP_MemoryCollection
Property name
Property implementation
CIM_ManagedElement
Caption
Memory Collection
Description
Physical memory collection
ElementName
Memory Collection
CIM_SystemSpecificCollection
InstanceID
HPQ:HP_MemoryCollection:001
HP_GroupSystemSpecificCollection