HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 6-7 HP_SensorHardwareIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name
Property implementation
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A temperature sensor has detected that the temperature
has returned to a normal operating range.
(SensorCaption)‖, where SensorCaption is the
HP_WinNumericSensor.Caption for the temperature
sensor detecting a recovered exceeded threshold.
AlertingManagedElement
WBEM path of the HP_WinNumericSensor instance
representing the temperature sensor detecting a
recovered exceeded threshold
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Temperature
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Threshold exceeded condition recovery.
EventCategory
23 (System Cooling)
ProbableCause
52 (Threshold Crossed)
ProbableCauseDescription
Threshold Exceeded Condition has Recovered
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>