HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 6-2 Class: HP_NumericSensor
Property name
Property implementation
Description
Temperature Sensor n detects for NumericSensorType.
StatusDescription.
n represents the number of the temperature sensor
instance, NumericSensorType represents the value of
NumericSensorType and StatusDescription represents
the value of StatusDescriptions[0]
ElementName
Temperature Sensor n, where n represents the number
of the temperature sensor instance.
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK)—If temperature reported by the sensor is
within normal operating range
2 (OK)—If temperature reported by the sensor has
exceeded its non-critical threshold and has set fans
to full speed
6 (Error)—If temperature reported by the sensor has
exceeded its threshold and the system is gracefully
shutting down
StatusDescriptions[0]
Temperature reported by the sensor is within
normal operating range—If temperature reported
by the sensor is within normal operating range;
Temperature reported by the sensor has exceeded
its non-critical threshold and the fans have been set
to full speed—If temperature reported by the sensor
has exceeded its threshold and has set fans to full
speed
Temperature reported by the sensor has exceeded
its threshold and the system is gracefully shutting
down—If OperationalStatus is 6 (Error)
HealthState
5 (OK)—If OperationalStatus[0] value is 2 (OK)
20 (Major Failure)—If OperationalStatus[0] value is
6 (Error)
Name
Temperature Sensor n, where n represents the number
of the temperature sensor instance
CIM_LogicalDevice
CreationClassName
HP_WinNumericSensor
DeviceID
Unique identifier for this temperature sensor instance.
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)