HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 5-26 HP_SensorHardwareIndication: Fan Redundancy Gained
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber
Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-9 Fan Redundancy Restored
Table 5-27 HP_SensorHardwareIndication: Fan Redundancy Restored
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Cooling redundancy for the system has been restored.
(RedundancySetCaption), where RedundancySetCaption is
HP_WinCoolingRedundancySet.Caption of the cooling
redundancy set with restored redundancy
AlertingManagedElement
WBEM path of theHP_WinCoolingRedundancySet
instance representing the cooling redundancy set with
restored redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Cooling redundancy restored
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)